SHOP ONLINE NOW
Our E-Commerce Site is now live. You can view pricing and place orders directly online.
Siemens - 3RA6250-1CB32 SIRIUS COMPACT LOAD FEEDER REVERSING STARTER 690 V 24 V AC/DC 50...60 HZ 1...4 A IP20 CONNECTION MAIN CIRCUIT: SCREW TERMINAL CONNECTION CONTROL CIRCUIT: SCREW TERMINAL
3RA62501CB32
Manufacturer: Siemens
SIRIUS COMPACT LOAD FEEDER REVERSING STARTER 690 V 24 V AC/DC 50...60 HZ 1...4 A IP20 CONNECTION MAIN CIRCUIT: SCREW TERMINAL CONNECTION CONTROL CIRCUIT: SCREW TERMINAL
Available for Back Order
SIRIUS Compact load feeder Reversing starter 690 V 24 V AC/DC 50...60 Hz 1...4 A IP20 Connection main circuit: Screw terminal Connection control circuit: screw terminal compact starter SIRIUS 3RA62 for direct starting of standard three-phase motors up to 32 A.The devices combine the functions of circuit breaker, contactor and electronic overload relay and offer extremely high operational reliability. A low number of variants simplifies logistics. The compact design saves space in the control cabinet. Thanks to removable terminals, easy replacement is possible. The devices are approved for worldwide use (e.g. IEC and UL/CSA).The compact starters are available as direct-on-line or reversing starters and with various setting ranges. Designed for AC or DC operation, they are available with screw or spring-loaded terminals, or without terminals.In addition to the communication link via AS-interface, the 3RA68 infeed system and auxiliary contacts as well as terminals are available as accessories.Simple, efficient and always up to date - SIRIUS modular system.
Product Information
Manufacturer: | Siemens |
Pricing Unit: | Each |
Weight: | 2.579 kg (each) |
Tariff code: | 85364900 |
Generic code: | 121 |
GTIN/UPC/EAN: | 4011209715370 |
Product Details
ETIM Group: | Low-voltage industrial components |
ETIM Class: | Motor starter/Motor starter combination |
Ambient temperature, upper operating limit: | 60°C |
Coordination class according to IEC 60947-4-3: | Class 2 |
Degree of protection (IP): | IP20 |
Degree of protection (NEMA): | Other |
Depth: | 165mm |
External reset possible: | true |
Height: | 170mm |
Number of auxiliary contacts as normally closed contact: | 0 |
Number of auxiliary contacts as normally open contact: | 2 |
Number of command positions: | 2 |
Number of indicator lights: | 3 |
Overload release current setting: | 1 - 4A |
Rail mounting possible: | true |
Rated conditional short-circuit current, type 1, 480 Y/277 V: | - |
Rated conditional short-circuit current, type 1, 600 Y/347 V: | - |
Rated conditional short-circuit current, type 2, 230 V: | - |
Rated conditional short-circuit current, type 2, 400 V: | - |
Rated control supply voltage Us at AC 50HZ: | 24 - 24V |
Rated control supply voltage Us at AC 60HZ: | 24 - 24V |
Rated control supply voltage Us at DC: | 24 - 24V |
Rated operation current at AC-3, 400 V: | 4A |
Rated operation current Ie: | 4A |
Rated operation power at AC-3, 230 V, 3-phase: | - |
Rated operation power at AC-3, 400 V: | 1.5kW |
Rated power, 460 V, 60 Hz, 3-phase: | - |
Rated power, 575 V, 60 Hz, 3-phase: | - |
Suitable for emergency stop: | false |
Supporting protocol for ASI: | false |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for CAN: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Supporting protocol for LON: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for other bus systems: | false |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Supporting protocol for SERCOS: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for TCP/IP: | false |
Temperature compensated overload protection: | false |
Type of electrical connection for auxiliary- and control current circuit: | Screw connection |
Type of electrical connection of main circuit: | Screw connection |
Type of motor starter: | Reversing starter |
Voltage type for actuating: | AC/DC |
Width: | 90mm |
With fuse: | false |
With short-circuit release: | true |
With transformer: | false |
Dimensions (Unpackaged)
Quantity | Height | Width | Length | Weight |
---|---|---|---|---|
1 | 165 mm | 90 mm | 170 mm | 2395 g |
All shipping options below are for United Arab Emirates. Delivery prices below are Exc VAT.
Web Promo Carriage | UK standard delivery, usually within 1 - 2 days (1 per day, minimum order AED 2,000.00) | AED 0.00 |
Standard 1-2 Days | UAE standard delivery, usually within 1 - 2 days | AED 25.00 |
Collect | Collection is available from our site - please call if your order is urgent | AED 0.00 |
International Priority to Pakistan
(Terms DAP to Delivery Address)
For our overseas customers, we offer a very competitive and fast delivery service; however, if you prefer to collect using your own courier, then we can also arrange that at no extra cost.
Our technical team can help find an alternative! Fill in the below to get started.